DeviceNet inclinometer

• Vigor Technology DeviceNet
• According to DeviceNet Slave protocol
• Support UCMM explicit message server, client
• Support all kinds of messages, offline connectivity
• Support 5K-1000Kbps total 15 kinds of CiA recommended
• Non-volatile memory storage network parameters, slave station configuration protocol file connectivity
• Built-in high-speed optical isolation
• ODVA certified communication cable

Downloads

Datasheet

Product info

DeviceNet inclinometer is based on Vigor patent tilt measurement technology and combined with DeviceNet interface. It shortens system building and debugging, reducing construction and maintenance costs.
DeviceNet inclinometer meets ODVA standards and implements industry-standard protocols, and has strong measuring ability:

  • ±0.02%FS linearity
  • ±0.005° Offset
  • Combine with gyro module to realize static/dynamic angle measuring for low/rapid leveling
  • With vibration module to realize in-time FFT computations; outputs vibration frequency and amplitude directly, eliminating environmental vibration influence
  • Combine with GPS module to realize data synchronization/acquisition and local position data at different installation places
  • Performance confirmed for offset, repeatability, hysteresis, and turn-on repeatability
  • Enhanced algorithms drastically reduce cross-axis error and improve true tilt accuracy
  • Greatly reduced errors when the real tilt direction is not consistent with the unit’s sensitive axis
  • Short-circuit, transient voltage, and transposition protections for industrial environments
  • Users can set all parameters via DeviceNet interface and query factory data

DeviceNet Inclinometer supports the DeviceNet standard protocol, enabling point-to-point or point-to-multipoint communication; suitable for high interference, high real-time requirements, and high-capacity data transmission.
It can directly connect and communicate with various PLCs in real time.

A DeviceNet network can support up to 64 nodes. End-to-end distance depends on network speed: at 125 kbps, max distance up to 500 m; at 500 kbps, max distance up to 100 m.
The bus topology is a trunkline–dropline linear bus. C16 cable option (data and power in one cable) offers an extensive line-up of inclinometers for DeviceNet applications.

Ordering

DeviceNet inclinometer ordering chart

Example: dual-axis DeviceNet inclinometer, range ±15°, room temperature accuracy ±0.02°, −20~60 ℃ temperature drift ±0.02°, DeviceNet interface output, 15 m cable with plug, vibration function module — model:
SST302-15-G6-F5-00-C13-D3 (15m).

Table 3 — Accessories

Item Order Code Accessories Name Function
Functional model (built-in) F1 GPS module Positioning accuracy 2.5 m CEP; 2.0 m @ SBAS
Local gravity acceleration automatic revision
Time pulse accuracy: 30 ns RMS; raw data 4 Hz
Speed accuracy: 0.1 m/s; GPS L1 band, C/A code;
Higher-accuracy GPS available
F4 Gyro module ±100/250/400°/s X/Y/Z dynamic angular rate;
In-run bias: ±0.02°/s; Non-linearity: 0.1%FS;
Bandwidth: 50 Hz; Noise density: 0.02°/s/√Hz;
Higher-accuracy gyro available
F5 Vibration module Three-axis detection; frequency response ≤5 kHz;
Range: 0g~±1g/±5g/±10g/±20g (adjustable);
Real-time sampling: 20.48 kSPS; programmable filter (11 set points);
FFT 512-point, real-valued on x/y/z; stores 14 FFT records (x/y/z);
Programmable alarm (6 spectrums)
Temperature drift D1 Temperature drift Compensation 0~60 ℃, accuracy ±0.01° @ ≤±30°
D2 Temperature drift Compensation 0~60 ℃, accuracy ±0.01° @ >±30°
D3 Temperature drift Compensation −20~60 ℃, accuracy ±0.02° @ ≤±30°
D4 Temperature drift Compensation −20~60 ℃, accuracy ±0.02° @ >±30°
D5 Temperature drift Compensation −30~60 ℃, accuracy ±0.03° @ ≤±30°
D6 Temperature drift Compensation −30~60 ℃, accuracy ±0.03° @ >±30°
D7 Temperature drift Compensation −40~65 ℃, accuracy ±0.05° @ ≤±30°
D8 Temperature drift Compensation −40~65 ℃, accuracy ±0.05° @ >±30°
D9 Temperature drift Compensation −40~85 ℃, accuracy ±0.05° @ ≤±30°
D10 Temperature drift Compensation −40~85 ℃, accuracy ±0.05° @ >±30°

Table 4 — Options

Item P/N Option Name Function
Network access device SST003-05-14 8-ports industrial switch 8×100 Mb network; VLAN (IEEE 802.1q);
Fast redundant ring protection (ITU-T G.8032 V2), failover <5 ms;
Supports RSTP/STP; IEEE 802.1x authentication;
Broadcast storm suppression; Level 3 industrial EMC;
Operating temperature −10~+60 ℃.
Power SST003-09-04 PoE Power IEEE 802.3af PI (PSE/PD over network cable);
Alternative A (1,2,3,6 signal pairs) and Alternative B (4,5,7,8 spare pairs).