3DM-CV5-IMU

• High Performance Accelerometer
• 100 µg/√Hz (8g standard)
• 2g, 4g, 20g, 40g options
• Super-stable Gyro
8 dph in-run bias (-40 to +85°C)
Offset temperature hysteresis 0.05°/s
ARW 0.3 °/√hr
• Adjustable sampling rates up to 1000Hz
• Forward compatible MIP Protocol optimizes bandwidth
• Configurable IMU outputs
• SensorConnect software for configuration, control, display, and logging

The 3DM-CV5 family of industrial-grade, board-level inertial sensors provides a wide range of triaxial inertial measurements, computed attitude, and navigation solutions.

In all models, the Inertial Measurement Unit (IMU) includes direct measurement of acceleration, angular rate, delta theta, and delta velocity. Compensation options include automatic compensation for magnetic anomalies, gyro and accelerometer noise, and noise effects. In models that include computed outputs, sensor measurements are processed through and auto-adaptive estimation filter algorithm to produce high accuracy computed outputs under dynamic conditions. The computed outputs vary between models and can include roll, pitch, and yaw.

All sensors are fully temperature-compensated and calibrated over the operating temperature range. The use of Micro-ElectroMechanical Systems (MEMS) technology allows for highly accurate, small, light-weight devices.

SensorConnect software is a user friendly program for device configuration. MIP Monitor (MicroStrain Inertial Protocol) can also be used. Both packages provide for device configuration, live data monitoring, and recording.
Alternatively, the MIP Data Communications Protocol is available for development of custom interfaces and easy OEM integration.
The sensor operates independent of computer platform, operating system, or coding language.

3DM-GV7-AHRS
Specification Value
General
Integrated Sensors Triaxial accelerometer, triaxial gyroscope, and temperature sensors
Data Outputs Inertial Measurement Unit (IMU) outputs: acceleration, angular rate, Delta-theta, Delta-velocity
Inertial Measurement (IMU) Sensor Outputs
Accelerometer / Gyroscope
Measurement Range Accelerometer: ±8 g (std) ±2 g ±4 g ±20 g ±40 g (opt)
Gyroscope: ±500 °/sec (std) ±250 °/sec ±1000 °/sec (opt)
Non-linearity Accelerometer ±0.04 % fs | Gyroscope ±0.06 % fs
Resolution Accelerometer 0.05 mg (+/-8 g) | Gyroscope <0.003 °/sec (500 dps)
Bias Instability Accelerometer ±0.08 mg | Gyroscope 8 °/hr
Initial Bias Error Accelerometer ±0.004 g | Gyroscope ±0.01 °/sec
Scale Factor Stability Accelerometer ±0.05 % | Gyroscope ±0.05 %
Noise Density Accelerometer 100 µg/√Hz (2 g) | Gyroscope 0.0075 °/sec/√Hz (500 °/sec)
Alignment Error Accelerometer ±0.05 ° | Gyroscope ±0.08 °
Adjustable Bandwidth Accelerometer 225 Hz (max) | Gyroscope 500 Hz (max)
Offset Error over Temperature Accelerometer 0.02 % (typ) | Gyroscope 0.01 % (typ)
Gain Error over Temperature Accelerometer 0.05 % (typ) ±0.2 % (max) | Gyroscope 0.1 % (typ) ±0.4 % (max)
Sampling Rate 1 kHz (accelerometer & gyroscope)
IMU Filtering First stage sigma-delta ADC sampled at 1 kHz; second stage user-adjustable digital low-pass filter.
IMU Data Output Rate 1 Hz to 1000 Hz
Operating Parameters
Communication TTL serial (3.0 V dc, 9 600 bps to 921 600 bps, default 115 200)
Power Source +3.2 V to +5.2 V dc
Power Consumption 360 mW (typ), 500 mW (max)
Operating Temperature −40 °C to +85 °C
Mechanical Shock Limit 500 g / 1 ms absolute maximum survivability *
MTBF 1 035 471 hours (Telcordia method gm/35C)
Physical Specifications
Dimensions 38 mm × 24 mm × 9.7 mm
Weight 11 grams
Enclosure Material Aluminum
Regulatory Compliance CE, RoHS
Integration
Connectors Data/power output: Samtec FTSH Series. Connectivity board: Micro-D9
Software SensorConnect and MIP Monitor software included; Windows XP/Vista/7/8/10 compatible
Data Communications Protocol (DCP) Protocol compatibility across GX3, GX4, RQ1, GQ4, GX5, CX5 and CV5 product families
Software Development Kit (SDK) MicroStrain Communication Library (MSCL) open-source license includes full documentation and sample code
Hardware Development Kit Option purchased separately

* Prolonged exposure to > 2 × full-scale range can result in permanent damage. See manual for details.