3DM-GX5-IMU

• High Performance Accelerometer
• 25 µg/√Hz (8g option)
• 80 µg/√Hz (20g option)
• Super-stable Gyro
• 8 dph in-run bias (-40 to +85°C)
Offset temperature hysteresis 0.05°/s
ARW 0.3°/√hr
• Adjustable sampling rates up to 1000Hz
• Configurable IMU outputs
• Forward compatible MIP Protocol optimizes bandwidth
• SensorConnect software for configuration, control, display, and logging

The MicroStrain 3DM-GX5 family of high performance, industrial-grade inertial sensors provides a wide range of triaxial inertial measurements, computed attitude, and navigation solutions.
In all models, the Inertial Measurement Unit (IMU) includes direct measurement of acceleration and angular rate, and is fully temperature-compensated and calibrated over the operating temperature. The use of Micro-Electro-Mechanical

System (MEMS) technology allows for highly accurate, small, lightweight devices.
SensorConnect software is a user friendly program for device configuration. MIP Monitor (MicroStrain Internet Protocol) can also be used. Both packages provide for device configuration, live data monitoring, and recording.

Alternatively, the MIP Data Communications Protocol is available for development of custom interfaces and easy OEM integration.
The sensor operates independent of computer platform, operating system, or coding language.

General
Integrated Sensors Triaxial accelerometer, triaxial gyroscope and temperature sensors
Data Outputs Inertial Measurement Unit (IMU) outputs: acceleration, angular rate, ambient pressure, Delta-theta, Delta-velocity
Inertial Measurement (IMU) Sensor Outputs
Accelerometer Gyroscope
Measurement Range ±8 g (standard) ±2 g, ±4 g, ±20 g, ±40 g (optional) ±300°/sec (standard) ±75, ±150, ±900 (optional)
Non-linearity ±0.02% fs ±0.02% fs
Resolution 0.02 mg (+/- 8 g) <0.003°/sec (300 dps)
Bias instability ±0.04 mg 8°/hr
Initial bias error ±0.002 g ±0.04°/sec
Scale factor stability ±0.03% ±0.05%
Noise density 20 µg/√Hz (2 g) 0.005°/sec/√Hz (300°/sec)
Alignment error ±0.05° ±0.05°
Bandwidth 225 Hz 250 Hz
Offset error over temperature 0.06% (typ) 0.04% (typ)
Gain error over temperature 0.03% (typ) 0.03% (typ)
Vibration induced noise 0.072°/s RMS/g RMS
Vibration rectification error (VE) 0.03% 0.001°/s/g RMS
Sampling rate 1 kHz 4 kHz
IMU Filtering Digital sigma-delta ADC sampled at 1 kHz and 4 kHz. 4 kHz data averaged to 1 kHz nominal sampling rate. Scaled into physical units at 1 kHz. User adjustable IIR filter available for 1 kHz data. Coning and sculling integrals computed at 1 kHz.
IMU data output rate 1 Hz to 1000 Hz
Operating Parameters
Communication RS232 (9,600 bps to 921,600 bps, default 115,200)
Power source +4 to +36 V dc
Power consumption 300 mW (typ)
Operating temperature -40 °C to +85 °C
Mechanical shock limit 500 g / 1 ms absolute maximum survivability *
MTBF 557,280 hours (Telcordia method, GM/35C)
Physical Specifications
Dimensions 36.0 mm × 36.6 mm × 11 mm
Weight 16.5 g
Enclosure material Aluminum
Regulatory compliance CE, REACH, RoHS
Integration
Connectors Data/power output: Micro-D9
Software SensorConnect and MIP Monitor software included; Windows XP/Vista/7/8/10 compatible
Data Communications Protocol (DCP) Protocol compatibility across GX3, GX4, RQ1, GQ4, GX5, CX5 and CV5 product families
Software Development Kit (SDK) MicroStrain Communication Library (MSCL) open source license includes full documentation and sample code

* Prolonged exposure to > 2 × full-scale range can result in permanent damage. See manual for details.