USB320

  • USB 2.0 Communication Link
  • Sampling Rate: up to 4800 Samples Per Second
  • Up to ±50,000 count (noise-free)
  • Amplified (Current Or Voltage) input (selectable up to ±10V or 0-20 mA)
  • Up to 16 Point Stored Calibration
  • ASCII stream output
  • High resolution, high accuracy and low non-linearity
  • CE approval and RoHS compliant

Product Description

The USB320 – External USB Kit (Amplified Input) module eliminates the need for power supply and display equipment. The module is powered directly by PC through a USB cable, providing excitation voltage for the sensor. The analog output voltage of the sensor is digitized and processed by a microprocessor using an integrated high-resolution (24-bit) analog-to-digital converter (ADC).

The onboard USB device allows the microprocessor to communicate with the PC through the USB link. Integration with SENSIT Test and Measurement Software enables users to monitor sensor output in real time, calculated based on calibration data stored in the onboard memory.

With easy plug-and-play functionality, users can monitor sensor output with minimal impact from noise, temperature variation, and excitation instability. The USB320 is designed and manufactured by FUTEK in the USA.

FSH03634

  • USB 2.0 Communication Link
  • Sampling Rate: up to 4800 Samples Per Second
  • Up to ±50,000 count (noise-free)
  • Amplified (Current only) input
  • Up to 16 Point Stored Calibration
  • ASCII Stream Output
  • High Resolution, High Accuracy, and Low Non-Linearity
  • CE Approved and RoHS Compliant
NAME MIN TYP MAX UNIT
Excitation 12 Vdc
Nonlinearity -0.01 0.01 % of R.O.
Operating Temperature -13 185 °F
Sample Rate 10 4800 Samples/sec
Communication Interface USB
Power Supply 5 Vdc
Storage Temperature -40 257 °F
Input Range 0 20 mA
Weight 10 Gram

FSH03631

  • USB 2.0 Communication Link
  • Sampling Rate: up to 4800 Samples Per Second
  • Up to ±50,000 count (noise-free)
  • Amplified (Voltage only) input
  • Up to 16 Point Stored Calibration
  • ASCII Stream Output
  • High Resolution, High Accuracy, and Low Non-Linearity
  • CE Approved and RoHS Compliant
NAME MIN TYP MAX UNIT
Excitation 12 Vdc
Nonlinearity -0.01 0.01 % of R.O.
Operating Temperature -13 185 °F
Sample Rate 10 4800 Samples/sec
Communication Interface USB
Power Supply 5 Vdc
Storage Temperature -40 257 °F
Input Range -10 10 Vdc
Weight 10 Gram