• Micro-Measurement M-Bond AE-10
• 6 Jars
• Two-component epoxy system
• Highly resistant to moisture and most chemicals
• Easy to use
Two-component, 100%-solids epoxy system for general-purpose stress analysis.
Transparent, medium viscosity. Cure time as low as six hours at +75°F [+24°C] may be used.
Elevated-temperature post-cure is recommended for maximum stability, and/or tests above room temperature.
Highly resistant to moisture and most chemicals, particularly when post-cured.
For maximum elongation, bonding surface must be roughened. Cryogenic applications require very thin glue lines.
For proper results, the procedures and techniques presented here should be used with qualified
Micro-Measurements installation accessory products. Those used in this procedure are:
We include all this in our start kits — all your adhesive needs packed in a handy tool box.
| Kit | Description |
|---|---|
| Startkit M-Bond AE-10/15 1 | Complete starter kit containing M-Bond AE-10/15 adhesive and all required Micro-Measurements installation accessories. |
| Startkit M-Bond AE-10/15 2 | Extended kit including additional consumables and tools for repeated lab or field installations. |
Copyright 2025 © All rights Reserved. Hemsida Webbdesign Interwebsite Webbyrå